Weigh Averaging
Purpose
Use this program to determine weights under
unstable ambient conditions. In this program, the
balance/scale calculates the weight as the average
value from a defined number of individual weighing
operations. These weighing operations are also
known as “subweighing operations” or “subweighs.”
Available Features
The measured result displayed is the arithmetic
mean shown in the selected weight unit;
a triangle indicates that this is a calculated value
You can set the number of subweighing
operations performed in the operating menu:
See “Configuring the Balance/Scale”
Press v for at least 2 sec. to display
the preset number of subweighing operations
Press v to toggle the display between
the calculated result and the weight
Factory Settings
Number of subweighs for averaging: 10 (3. 3. 2)
Preparation
§ Configure the Weigh Averaging application
in the operating menu:
See “Configuring the Balance/Scale”
Menu code 2. 1.12 Averaging
Number of subweighs for weigh averaging:
3. 3. 1 5 subweighs
3. 3. 2 10 subweighs
3. 3. 3 20 subweighs
3. 3. 4 50 subweighs
3. 3. 5 100 subweighs
See also “Configuring the Balance/Scale”